佐野 雄一; 坂本 淳志; 小藤 博英; 竹内 正行
Proceedings of 21st Pacific Basin Nuclear Conference (PBNC 2018) (USB Flash Drive), p.314 - 318, 2018/09
遠心抽出器の運転条件がUの抽出挙動に与える影響について、液相(水相及び有機相)間の物質移動を考慮した、乱流数値モデルに基づいたCFD解析により評価した。ロータ回転数や有機相/水相流量比の違いによる抽出挙動の変化について、実験により得られた傾向を概ね再現できることを確認した。
大釜 和也; 大木 繁夫; 北田 孝典*; 竹田 敏一*
Proceedings of 21st Pacific Basin Nuclear Conference (PBNC 2018) (USB Flash Drive), p.942 - 947, 2018/09
A core concept of minor actinides (MAs) transmutation with improved safety was designed by applying sodium plenum and axially heterogeneous configuration. In this study, heterogeneous MA loading methods were developed for the core concept to explore the potential of further improvement of MA transmutation amount and "effective void reactivity" which was introduced by assuming the axial coolant sodium density change distribution for the unprotected loss of flow accident. By investigating characteristics of heterogeneous cores loading MA in different radial or axial positions, preferable MA loading positions were identified. The core loading MA in the radial position between inner and outer core region attained the largest MA transmutation amount and lowest maximum linear heat rate (MLHR) among heterogeneous cases. The lower region of the core was beneficial to improve the effective void reactivity and MLHR maintaining the nearly same MA transmutation amount as that of the homogeneous core. The radial blanket region was also useful to increased MA transmutation amount without deterioration of the effective void reactivity.